Energy Savings

Each kW of compressed air is 7-8 times more expensive than a kW of electricity. Chicago Pneumatic set up a service with the objective to identify and quantify energy & cost savings with respect to generation of compressed air.

  • Most compressor installations run at too high pressure (most end uses are designed to operate between 80-125 psig)
  • Every 1 bar/14.5 PSI drop in pressure output, reduces energy consumption by around 7%
  • Most compressor systems are not shutdown during non production hours, wasting huge amounts of compressed air to leakages
  • Most multiple compressor systems do not have central controller to anticipate fluctuations in air demand
  • In most compressor systems no Variable Speed compressor is installed to anticipate fluctuations in air demand

VSD Compressor savings
The V(ariable) S(peed) D(drive) regulating system offers the capability to match perfectly compressor capacity to air demand. 

Frequency driven units: VSD Regulation

The V(ariable) S(peed) D(drive) regulating system offers the capability to match perfectly compressor capacity to air demand.

A VSD system is able to follow the fluctuating demand by varying the speed of its drive motor by means of a frequency converter. As air demand goes down, the VSD lowered the delivered flow and consequently the power consumption. This is the key feature of the VSD regulating system: they reduce the energy consumption to a minimum by avoiding completely un-loaded power consumption and save up to 22% on the total life cycle cost (LCC). 





VSD Compressor savings
  




SUPERIOR REGULATION

SUPERIOR REGULATIONS SAVES ENERGY
CPVS offers the ultimate advantages by its superior regulation


Reduction Energy Cost by 35%
The CPVS regulation follows the air consumption fast and exactly, thus saving the maximum of energy. 

Stable System Pressure
The CPVS controls the sytem pressure within 2 psi, reducing the system pressure.  

High Power Factor
The CPVS increases the power factor of your electrical network.  

No Starting Peaks
The CPVS does not generate any starting peaks thus reducing the load and sensitivity of your electrical network.  

Reduction Air Receiver Capacity
Installing a CPVS allows you to reduce the air receiver volume.          

 

                                           EMAIL kyle@nawonusa.net for more information

NAWON USA INC. IS READY TO HELP YOU


NAWON USA, INC.
7322 VALJEAN AVE. VAN NUYS CA 91406
Phone: 818-782-5100 • Toll Free: 800-983-7111 • Fax: 818-782-5102
2014 © Copyright Nawon USA. All rights reserved.

NAWON USA is not affiliated with SONOBOND, we are an independant repair and parts facility.

*To the extent NAWON USA uses trademarks, servicemarks, tradenames, or other identifying information of other companies, NAWON USA is making use of those Trademarks for identification or is making use by permission. The owner of the Trademarks has not consented to further use or copying of the trademarks and NAWON USA can not license such. Sonobond, Lacemaster, Seam master, SM86, LM920, RINGMASTER and any words prefixed by the word SONOBOND or SONOBOND's trademarks which all belong to SONOBOND. Chicago Pneumatic, JUKI, Brother, Mitsubishi, Efka, PFAFF, FRAMIS ITALIA, ARMDEL, Etc. are all trademarks of their respectful owners.This is not necessarily a full list of trademark notifications we must make, if you feel we have missed one, please contact us at 800-983-7111 to have it added.